576芯插片式光缆交接箱规格型号

2025-05-27 09:03 39.188.221.139 1次
发布企业
宁波市伊特尔通信设备有限公司商铺
认证
资质核验:
已通过营业执照认证
入驻顺企:
5
主体名称:
宁波市伊特尔通信设备有限公司
组织机构代码:
91330282MA281E3J6E
报价
人民币¥1400.00元每件
品牌
伊特尔
尺寸
1450*750*540
产地
浙江 宁波
关键词
576芯落地式光交箱,576芯SMC光交箱,576芯不锈钢光交箱,576芯免跳接光交箱,576芯插片式光交箱
所在地
慈溪市附海镇海晏庙村
联系电话
13336682886
全国服务热线
13656843688
经理
李承猛  请说明来自顺企网,优惠更多
请卖家联系我

产品详细介绍

144芯光缆交接箱

一、 概述 
One, overview

1. 本产品是用于光纤接入网中主干光缆与配线光缆节点的连接设备,可以实现光纤的

1 this product is usedfor connecting devices in optical access network of trunk opticalcable and wiring cable node, can realize the opticalfiber

熔接.存储以及分配调度等功能。产品技术标准符合YD/T988-2007。

Weld. Storage anddistribution scheduling and other functions. Products conform tothe technical standard of YD/T988-2007.

2. 特点 1)箱体采用高强度SMC不饱和聚脂防腐蚀特种合成材料制作,具有高隔热性,能

The 2 features 1) boxmade of high strength SMC unsaturated polyester corrosionprevention special synthetic materials, has high heat insulation,energy

抵御剧变气候和恶劣的工作环境.

Resist the upheaval ofclimate and poor working environment.

2) 箱体采用定位门锁,生久品牌锁,安全可靠。 3)可以实现光缆的互联,交叉连接和光纤的盘储。 4) 有可靠的光缆固定和接地保护装置。 5)使用熔接配线一体化模块,适合FC,SC光纤适配器卡装;并可放入分路器进行

2) the box body adoptsa positioning lock, life long brand lock, safe and reliable. 3)interconnection can realize optical cable, cross connection andfiber disc storage. 4) have reliable optical cable fixing andgrounding protection device. 5) using fused wiring integrationmodule, suitable for FC, SC optical fiber adapter card installed;and can be placed in the channelizer

光分配。

The lightdistribution.

6) 光纤的分配和调度均为全正面化操作。 3. 技术指标1)使用条件

6) fiber allocation andscheduling are all positive operation. The 3 technical indicators1) conditions of use

环境温度:-20℃~+60℃贮运温度:-25℃~+55℃ 相对湿度:≤95%(+40℃时) 大气压力:70Kpa~106Kpa 2)光电性能

Ambient temperaturefrom-20 DEG to 60 C storage temperature: - 25 DEG C: 55 relativehumidity is less than or equal to 95% (40 C) atmospheric pressure:70Kpa~106Kpa 2) photoelectric properties

连接器插入损耗(包括插入、互换、重复)≤0.2dB

Connector insertionloss (including insert, swap, repeat) is less than or equal to0.2dB

回波损耗:FC/PC≥45dBFC/UPC≥50 dB FC/APC≥60 dB 插拔耐久寿命大于1000次。 4. 箱体特点

The return loss isgreater than or equal to 45dB: FC/PC FC/UPC = 50 dB FC/APC = 60 dBplug endurance life is more than 1000 times. 4 housingcharacteristics

1) 机箱密封防护等级:GB4208/IP65

1) case sealingprotection grade: GB4208/IP65

2) 静负荷能力:箱壳≥980N 侧表面≥500N门铰链≥200N

2) static loadcapacity: a box shell > 980N > 500N side surface door hingeis greater than or equal to 200N

3)绝缘电阻:高压防护地与机架间绝缘电阻大于1000MΩ(500V/DC)

3) insulationresistance: high pressure protection and frame insulationresistance greater than 1000M (500V/DC)

4)耐电压强度:高压防护地与机架间通以直流电3000V历时1分钟不击穿且无飞弧现象发生。

4) voltage endurance:high voltage protection and rack communicated with 3000V DC for 1minutes without breakdown and no arc phenomenon.

光缆接续盒,又叫光缆接头盒和炮筒,是光缆的端头接入的地方,阻止大自然中热,冷,光,氧和微生物引起的材料老化,并且具有优良的力学强度,坚固的光缆接头盒外壳及主体结构件能够忍受Zui恶劣的环境变化,起到阻燃,防水作用,使震动,撞击,光缆拉伸,扭曲等得到保护。 

光缆接续盒内部结构

  1,支撑架:是内部构件的主体。

  2,光缆固定装置:用于光缆与底座固定和光缆加强元件固定。一是光缆加强芯在内部的固定;二是光缆与支撑架夹紧的固定;三是光缆与接头盒进出缆用热缩护套密封固定。

  3,光纤安放装置:能有顺序地存放光纤接头和余留光纤,余留光纤的长度应不小于1米,余留光纤盘放的曲径不小于35mm。其中收容盘多可四层,容量较大,并能根据光缆接续的芯数调整收容盘。

  4,光纤接头保护:把热缩后的保护套管放在收容盘里的纤芯固定夹上也可采用硅胶固定法。

  5,光缆与接头盒密封:对光缆及底座进缆处用砂布将接头盒和光缆的交接处进行打磨,用清洁剂把打磨处擦干净,贴上铝箔,再将热缩管放在接头盒的入缆处,用喷灯按照先中间后向两端缓慢加热,使整个热缩管完全收缩即可。

用途

  适用于各种结构光缆的架空,管道,直埋等敷设方式之直通和分支连接。

  结构光缆的终端机房内的接续。

光缆接续盒通常适用于室内或非露天的室外使用,不适合于露天使用,如要使用,应采取保护措施。工作温度:室内型:-5℃~40℃;室外型:-20℃- 60℃。

特点

  能起到保护和接续的作用,盒体采用增强塑料,强度高,耐腐蚀,结构成熟,密封可靠,施工方便 。

分类

按光缆连接方式,可分为直通型和分歧型。

  按是否可以装配适配器分类,可以分为可装配适配器型和不可装配适配器型。

  按外壳材料分类,可分为塑料外壳和金属外壳。


所属分类:中国通信产品网 / 通讯产品加工
576芯插片式光缆交接箱规格型号的文档下载: PDF DOC TXT